Related parameters
●Input voltage: three-phase AC380±10%, 50HZ/60HZ
● Output voltage: 0-50V, 0-60V, 0-70V, 0-80V, 0-90V, 0-100V (can be customized according to requirements)
● Output current: 0-500A, 0-750A, 0-1000A, 0-1500A, 0-2000A, 0-3000A, 0-4000A, 0-5000A, 0-6000A, 0-8000A (can be customized according to requirements)
●Adjustment mode: intelligent digital adjustment and manual analog stepless double adjustment
●Adjustment range: current 0-large value, voltage 0-large value, intelligent human-machine touch screen, PLC intelligent adjustment
● Output display: intelligent human-machine touch screen display and digital voltage, ammeter dual display
● Output frequency: 30KHZ DC square wave
● Output time: A total of 20 working hours control + 20 slow rise time control can be set
● Output segment waveform: set by customer according to customer's process requirements
●Storage files: 15 (for customers to store preset processes, convenient for next call)
● Operating environment: -15 ~ 40 ° C
● Storage temperature; -20 ~ 50 ° C
● Control accuracy: ≤1%
●Insulation resistance: input-output: ≧5MΩ;
● Input - chassis: ≧ 5MΩ;
● Output - chassis; ≧ 5MΩ;
●Insulation strength: input-output: AC1500V, 10mA, 1 minute;
●Input - chassis: AC1000V, 10mA, 1 minute
●Insulation class: Class B
●Protection level: IP20
●Cooling system: water-cooled
●Operation status: working mode can work continuously for a long time at full load
● Protection mode: phase loss, overheating, overcurrent, short circuit, undervoltage, overvoltage protection